Menu
Value
Notes

B037

0

Unlock parameters

A001

2

Frequency source Set to 1 to enable potentiometer

A002

2

Run command source

A004

400

Max frequency

A003

400

Base frequency

A082

220

AVR voltage

A044

3

Set Sensorless Vector Control Will not work with 2 motors per drive

B012

Set equal to motor amperage

H002

2

Motor constant selection

H003

2.2

Motor capacity

H004

2

Poles setting

H001

2 -> Run

Run spindle. Auto detection ___ should appear when successful

B083

Increase value in case of weird sound. Read manual.

F001

400

Control spindle speed by setting this parameter. Can be changed while spindle is on.